COMPANY HEADER
Terms
Stop coupling is sometimes referred to as a double bell coupling.
Request Information
Unit of Measure
Items
Stop Couplings

1 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Stop Coupling

Stop Couplings

1 1/4 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Stop Coupling

Stop Couplings

1 1/2 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Belowground Stop Coupling

Stop Couplings

1 1/2 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Stop Coupling

Stop Couplings

3 1/2 Inch (in) Nominal Size Standard Wall Iron Pipe Size (IPS) Aboveground Stop Coupling
Description N/A Stop coupling is sometimes referred to as a double bell coupling.
Brands N/A Champion Fiberglass®, Inc.
Type N/A Iron Pipe Size (IPS) Aboveground Stop Coupling N/A Iron Pipe Size (IPS) Aboveground Stop Coupling N/A Iron Pipe Size (IPS) Belowground Stop Coupling N/A Iron Pipe Size (IPS) Aboveground Stop Coupling N/A Iron Pipe Size (IPS) Aboveground Stop Coupling
Nominal Size N/A 1 in N/A 1 1/4 in N/A 1 1/2 in N/A 1 1/2 in N/A 3 1/2 in
Wall Thickness N/A Standard Wall
D N/A 1.32 in34 mm N/A 1.67 in42 mm N/A 1.91 in49 mm N/A 1.91 in49 mm N/A 3.52 in89 mm
L N/A 6 in152 mm
Conduit Type N/A Coupling
Color N/A Black
Weight N/A 0.04 kg0.09 lb N/A 0.04 kg0.09 lb N/A 0.05 kg0.11 lb N/A 0.05 kg0.11 lb N/A 0.14 kg0.30 lb
Industry Standards/Certifications N/A Underwriters Laboratories (UL)
Application N/A
Features N/A Most Commonly used.
General Information N/A N/A N/A Fiberglass Conduit Specifications for Use Below Ground

The conduit shall be fiberglass conduit, also known as Reinforced Thermosetting Resin Conduit (RTRC), manufactured using the single circuit filament winding process. Multi circuit windings are not allowed. The conduit shall have a winding angle as close as possible to 54.75 degrees.

The resin system shall be epoxy based, with no fillers, using an anhydride curing agent. The fiberglass shall consist of continuous E-glass roving. The conduit shall not contain any halogen compounds containing chlorine, bromine, fluorine and iodine in more than trace amounts when burning.

Conduit and elbows shall be manufactured from the same resin/hardener/glass systems manufactured by the same filament wound system.

Fiberglass conduit fittings and accessories shall be manufactured using one of two manufacturing procedures. The first method shall use the same process, methods, and components as used to manufacture the fiberglass conduit. The second method shall use the compression molding process, Sheet Molding Compound (SMC), for the manufacture of the finished component. The SMC material shall be a vinyl ester resin with +30% reinforcement of glass. The glass fibers should be approximately 1" in length. The SMC material shall be fire resistant to UL 2515.

Conduit shall be integral bell and spigot or bonded coupling and spigot.

Conduit, elbows and fittings are specified for use throughout a temperature range of -60ºF (-51ºC) to 250ºF (121ºC).

Manufacturer shall have a current Certificate of Compliance, issued by an independent and accredited company, with an ISO 9001:2008 Quality Management System.
N/A N/A